Eaton 9390 UPS

Formerly Powerware 9390 UPS

Eaton 9390 UPS combines technical innovation with a rich feature set to provide best-in-class power protection with high energy density for data-centers, medical facilities and other critical systems. Premium level efficiency cuts utility costs and with double conversion topology there are no compromises in reliability. Scalable runtimes and HotSync paralleling technology ensure this UPS system will fit your current and future power requirements.
Find a Reseller for this UPS

 

Eaton 9390 UPS - Technical Specifications

Product Snapshot
Power Rating 40-160 kVA
Voltage 400 V
Frequency 50/60 Hz
Configuration Tower
Product Series Powerware
UPS Models
Eaton 9390
Eaton 9390 (40-160 kVA) Specifications

Eaton 9390 UPS - Features

  • Leading sustainability is achieved with innovative UPS design and its high efficiency rating that significantly lower the total cost of ownership. Small footprint and lightweight reduce costs of transportation and installation.
  • Strong power performance with active power factor control (PFC) provides unbeatable 0.99 input power factor and minimizes THDi. This greatly reduces interference with other upstream equipment and enhances 9390 UPS compatibility with generators.
  • Highest availability and reliability is achieved with Powerware HotSync paralleling technology that enables 9390 UPS to be paralleled for both redundancy and capacity. Advanced paralleling options also ensure your UPS system can easily adapt to increasing power requirements.
  • Reliable backup with scalable runtimes are enhanced with Advanced Battery Management (ABM™) and UPS battery self test options that extent battery lifetime and help detect any defects in batteries already in earlier stage.
  • Robust manageability is delivered with advanced control and connectivity options and with superior service offering

Eaton 9390 UPS - Options

Power Distribution
Option Description Part Number
Eaton ePDU Enclosure Power Distribution Units distribute power to 4 to 45 receptacles in high-density rack environments. The plug-and-play architecture organizes power distribution, simplifies cable management and lets you add and change IT equipment without an electrician
Power Management
Option Description Part Number
CAN Bridge Card CAN Bridge Card for paralleling units and/or RMP/RIM/SCM interface. x2 for N+1, x3 for N+2 103004336
PowerVision Network Edition License Provides remote monitoring and computer operating system shutdown for multiple single-phase UPSs and small-to-midrange three-phase UPSs, from Eaton and others using industry-standard SNMP communications and integration with popular network management systems 165200132
PowerVision Facility Edition License Provides one-line detailed UPS information, monitors system status of other elements in the critical power distribution system such as generators, static switches, power distribution units (PDUs), and air conditioners through alarm contacts and supports in-depth reporting, analysis, and graphics 165200134
PowerVision Facilities Edition License Option 1: PowerVision Data Acquisition Terminal PowerVision Facilities Edition License Option 1: PowerVision Data Acquisition Terminal (Multiple PowerVision DATs may be installed on the same network and monitored by PowerVision Facility Edition simultaneously) 103003780
PowerVision Facilities Edition License Option 2: Wall Kit Option for PowerVision DAT PowerVision Facilities Edition License Option 2: Wall Kit Option for PowerVision DAT 103003916
Service Plans
Description Service Plan
  Standard Enhanced Premier
1 preventive maintenance visit/year (according to factory instructions; battery test, function test, alarm check-outs, cleaning, test report) Tick Tick Tick
Technical updates Tick Tick Tick
Repair service, 5 days per week 9-5pm mon/fri Tick    
Repair service, 7 days per week, 24 hours per day (7x24) 6 hr response   Tick  
Repair service, 7 days per week, 24 hours per day (7x24) 4 hr response     Tick
Hot-line assistance 24 hour Tick Tick Tick
Spare parts included (excludes batteries except under warranty) Tick Tick Tick
Emergency service, response within end of next working day Tick    
Emergency service, response within 6 hours, (round the clock service every day of the year)   Tick  
Emergency service, response within 4 hours, (round the clock service every day of the year)     Tick
Travel and labour costs included Tick Tick Tick
Repair labour included Tick Tick Tick

Eaton 9390 UPS - Support

Technical support is available to you in the event of a problem with your UPS

Eaton Power Quality Ltd
Tech & Service Support AC UPS Systems
T +44 (0) 1753 608 700
221 Dover Road
Slough, Berkshire
SL1 4RF
United Kingdom

 Hardware Support Form

 Software Support Form

E-mail this page Print this page
Copyright ©2009 Eaton Corporation.
All rights reserved.