Eaton 93PM UPS Technical Specifications

Standard UPS (with internal batteries)

Standard UPS without battery kit and batteries

Option

General
UPS output power rating (1.0 p.f.) 30, 40, 50, 80, 100, 120, 150, 160, 200 kW
Efficiency in double conversion mode Up to 97%
Efficiency in Energy Saver System (ESS) > 99%
Field upgradeable Yes
Inverter/rectifier topology Transformer-free IGBT with PWM
Audible noise 30–50 kW: < 60 dBA
80–200 kW: < 65 dBA
ESS operation: < 47 dBA
Altitude (max) 1000 m without derating (max 2000 m)
Input
Input wiring 3 ph + N + PE
Nominal voltage rating (configurable) 220/380, 230/400, 240/415 V 50/60 Hz
Input voltage range High +20% rectifier input, 10% bypass input
Low -15% at 100% load, -40% at 50% load without battery discharge
Input frequency range 40-72 Hz
Input power factor 0.99
Input ITHD 30 kW: < 4.5%
40–200 kW: < 3%
Soft start capability Yes
Internal backfeed protection Yes
Output
Output wiring 3 ph + N + PE
Nominal voltage rating (configurable) 220/380, 230/400, 240/415 V 50/60 Hz
Output UTHD < 1% (100% linear load); < 5% (reference non-linear load)
Output power factor 1.0
Permitted load power factor 0.8 lagging – 0.8 leading
Overload on inverter 10 min 102-110%; 60 sec 111-125%; 10 sec 126-150%; 300 ms > 150%.
On battery mode 300 ms > 126%
Overload when bypass available Continuous < 125%, 10 ms 1000%
Note: Bypass fuses may limit the overload capability!
Battery
Battery type VRLA
Charging method ABM technology or Float
Temperature compensation Optional
Battery nominal voltage (VRLA) 432 V (36 x 12 V, 216 cells) or 480 V (40 x 12 V, 240 cells)
Note: Strings with different battery voltage may not be paralleled!
Charging current maximum 30–50 kW 16.5 A
80–100 kW 33 A
120–150 kW 49.5 A
160–200 kW 66 A
Battery start capability Yes
Accessories
  External battery cabinets with long-life batteries, External maintenance bypass switch, integrated manual bypass (up to 150kW) MiniSlot connectivity (Web/SNMP, ModBus/Jbus, Relay)
Communications
Minislot 3 communication bays
Network/SNMP interface Yes, standard
Serial ports Built-in host and device USB
Relay inputs/outputs 5 relay inputs and dedicated EPO
1 relay output
Compliance with standards
Safety (CB certified) IEC 62040-1
EMC IEC 62040-2
Performance IEC 62040-3
Standard UPS (with internal batteries)
Model Description Rating Full load runtime Dimensions (WxDxH) mm Weight (with/without battery)
93PM-30(50) 30kW with internal battery, scalable to 50kW 30 kW Up to 20 minutes 560 x 914 x 1876 890/288 kg
93PM-40(50) 40kW with internal battery, scalable to 50kW 40 kW Up to 15 minutes 560 x 914 x 1876 890/288 kg
93PM-50(50) 50kW with internal battery 50 kW Up to 10 minutes 560 x 914 x 1876 890/288 kg
Standard UPS without battery kit and batteries
Model Description Rating Dimensions (WxDxH) mm Weight
93PM-50(100) 50kW, scalable to 100kW 50kW 560 x 914 x 1876 272 kg
93PM-80(100) 80kW, scalable to 100kW 80kW or 40kW N+1 560 x 914 x 1876 338 kg
93PM-100(100) 100kW system 100kW or 50kW N+1 560 x 914 x 1876 338 kg
93PM-50(150) 50kW, scalable to 150kW 50kW 560 x 914 x 1876 306 kg
93PM-100(150) 100kW, scalable to 150kW 100kW or 50kW N+1 560 x 914 x 1876 372 kg
93PM-120(150) 120kW, scalable to 150kW 120kW or 60kW N+1 560 x 914 x 1876 438 kg
93PM-150(150) 150kW system 150kW or 100kW N+1 560 x 914 x 1876 438 kg
93PM-160(200) 160kW, scalable to 200kW 160kW or 120kW N+1 760 x 914 x 1876 556 kg
93PM-50(200) 50kW, scalable to 200kW 50kW 760 x 914 x 1876 358 kg
93PM-100(200) 100kW, scalable to 200kW 100kW or 50kW N+1 760 x 914 x 1876 424 kg
93PM-150(200) 150kW, scalable to 200kW 150kW or 100kW N+1 760 x 914 x 1876 490 kg
93PM-200(200) 200kW system 200kW or 150kW N+1 760 x 914 x 1876 556 kg

Due to continuing product improvement programs, specifications are subject to change without notice.